Omron relays. General Purpose Relays. MY

Miniature Power Relays
MY

New Latching Levers for Circuit Checking Added to Our Best-selling MY General-purpose Relays

Model Number Structure

Structure Relays with Plug-in Terminals
948_lu_1_3
PCB
terminals

948_lu_1_4
Case-
surface
mounting

948_lu_1_5
Classification Number
of poles
With
operation
indicator
Without
operation
indicator
With latching
lever
Standard models
(compliant with
Electrical Appliances
and Material Safety Act)
2 MY2N * MY2 * MY2IN(S) * MY2-02 MY2F
Bifur-
cated
MY2ZN MY2Z
3 MY3N MY3 MY3-02 MY3F
4 MY4N * MY4 * MY4IN(S) * MY4-02 MY4F
Bifur-
cated
MY4ZN * MY4Z * MY4ZIN(S) * MY4Z-02 MY4ZF
Models with diode for
coil surge absorption
(DC coil specification
only)

948_lu_1_1
2 MY2N-D2 * MY2-D * MY2IN-D2(S) * --- ---
Bifur-
cated
MY2ZN-D2 MY2Z-D
3 MY3N-D2 MY3-D
4 MY4N-D2 * MY4-D * MY4IN-D2(S) *
Bifur-
cated
MY4ZN-D2 * MY4Z-D * MY4ZIN-D2(S) *
Models with CR circuit
for coil surge
absorption (AC coil
specification only)

948_lu_1_2
2 MY2N-CR * MY2-CR * ---
4 MY4N-CR * MY4-CR * MY4IN-CR(S) *
Bifur-
cated
MY4ZN-CR * MY4Z-CR * MY4ZIN-CR(S) *
Models with high
contact reliability
4 Bifur-
cated
--- MY4Z-CBG
Plastic sealed models 4 MYQ4N MYQ4 MYQ4-02
Bifur-
cated
MYQ4Z MYQ4Z-02
Latching models (coil
latching)
2 MY2K MY2K-02
Hermetic models 4 MY4H MY4H-0
Bifur-
cated
MY4ZH MY4ZH-0
Note: 1. The models in this table are UL/CSA certified. This is indicated with a certification mark on the products.
(This does not include models with high contact reliability or plastic sealed, latching, or hermetically sealed
models.)
2. Models with an asterisk (*) next to them are new versions.
3. The standard models with plug-in terminals, models with coil surge absorption diodes, and models with coil
surge absorption CR circuits were used in combination with the PYF[]A-E, PYF[]-S and PYF-[]-PU for the
EC Declaration of Conformity. These products display the CE Marking.
4. Products cannot be manufactured for the cells with a diagonal line. Ask your OMRON representative for details
on manufacturing products for cells containing "---" in the above table.

Miniature Power Relays: MY2

When your order, specify the rated voltage.

Classification
Model Rated voltage (V)
Standard products Made-to-order items
Standard models MY2 12, 24, 100/110, or 200/220 VAC 110/120 or 220/240 VAC
12, 24, 48, or 100/110 VDC
Models with built-in operation
indicators
MY2N 12, 24, 100/110, 110/120, 200/220, or 220/240 VAC
12, 24, 48, or 100/110 VDC
Models with built-in diodes MY2-D 12, 24, or 100/110 VDC 48 VDC
Models with built-in diodes and
operation indicators
MY2N-D2 12, 24, 48, or 100/110 VDC
Models with built-in CR circuits MY2-CR 100/110 or 200/220 VAC 110/120 or 220/240 VAC
Models with built-in CR circuits and
operation indicators
MY2N-CR 100/110 or 200/220 VAC 110/120 or 220/240 VAC
Note: 1. Ask your OMRON representative for details on the time required to deliver made-to-order products.
2. Ask your OMRON representative for details on product specifications and the ability to manufacture products
with voltages other than the above coil specifications.
3. The above models and specifications are new versions in the MY Series.
4. Except for MY2(N)-CR Relays with the above voltage specifications, all Relays have a height of 53 mm or less.
If Mounting Brackets are required, refer to catalog for selection information.

Miniature Power Relays: MY2Z

When your order, specify the rated voltage.

Classification
Model Rated voltage (V)
Standard products Made-to-order items
Standard models MY2Z 100/110 or 200/220 VAC 12, 24, 100/120, or 200/240 VAC
12 or 24 VDC 48 or 100/110 VDC
Models with built-in operation
indicators
MY2ZN 100/110 or 200/220 VAC 12, 24, 100/120, or 200/240 VAC
24 VDC 12, 48, or 100/110 VDC
Models with built-in diodes MY2Z-D 24 VDC 12 or 100/110 VDC
Models with built-in diodes and
operation indicators
MY2ZN-D2 24 or 100/110 VDC 12 VDC
Models with built-in CR circuits MY2Z-CR 100/110 or 200/220 VAC
Models with built-in CR circuits and
operation indicators
MY2ZN-CR 100/110 VAC 200/220 VAC
Note: 1. Ask your OMRON representative for details on the time required to deliver made-to-order products.
2. Ask your OMRON representative for details on product specifications and the ability to manufacture products
with voltages other than the above coil specifications.

Miniature Power Relays: MY3

When your order, specify the rated voltage.

Classification
Model Rated voltage (V)
Standard products Made-to-order items
Standard models MY3 24, 100/110, 200/220, or 220/240 VAC 12, or 110/120 VAC
12, 24, or 100/110 VDC 48 VDC
Models with built-in operation
indicators
MY3N 24, 100/110, 200/220, or 220/240 VAC 12, or 110/120 VAC
24 VDC 12, 48, or 100/110 VDC
Models with built-in diodes MY3-D 24 VDC 12 or 100/110 VDC
Models with built-in diodes and
operation indicators
MY3N-D2 24 VDC 12 or 100/110 VDC
Note: 1. Ask your OMRON representative for details on the time required to deliver made-to-order products.
2. Ask your OMRON representative for details on product specifications and the ability to manufacture products
with voltages other than the above coil specifications.

Miniature Power Relays: MY4

When your order, specify the rated voltage.

Classification
Model Rated voltage (V)
Standard products Made-to-order items
Standard models MY4 24, 100/110, or 200/220 VAC 12, 110/120, or 220/240 VAC
12, 24, 48, or 100/110 VDC
Models with built-in operation
indicators
MY4N 12, 24, 100/110, 110/120, 200/220,
or 220/240 VAC
12, 24, 48, or 100/110 VDC
Models with built-in diodes MY4-D 12, 24, 48, or 100/110 VDC
Models with built-in diodes and
operation indicators
MY4N-D2 12, 24, or 100/110 VDC 48 VDC
Models with built-in CR circuits MY4-CR 100/110 or 200/220 VAC 110/120 or 220/240 VAC
Models with built-in CR circuits and
operation indicators
MY4N-CR 100/110, 110/120, or 200/220 VAC 220/240 VAC
Note: 1. Ask your OMRON representative for details on the time required to deliver made-to-order products.
2. Ask your OMRON representative for details on product specifications and the ability to manufacture products
with voltages other than the above coil specifications.
3. The above models and specifications are new versions in the MY Series.
4. Except for MY4(N)-CR Relays with the above voltage specifications, all Relays have a height of 53 mm or less.
If Mounting Brackets are required, refer to catalog for selection information.

Miniature Power Relays: MY4Z

When your order, specify the rated voltage.

Classification
Model Rated voltage (V)
Standard products Made-to-order items
Standard models MY4Z 100/110 or 200/220 VAC 110/120 or 220/240 VAC
12, 24, 48, or 100/110 VDC
Models with built-in operation indicators MY4ZN 100/110 or 200/220 VAC 24, 110/120, or 220/240 VAC
24 or 100/110 VDC 12 or 48 VDC
Models with built-in diodes MY4Z-D 24 or 100/110 VDC 12 or 48 VDC
Models with built-in diodes and operation
indicators
MY4ZN-D2 12, 24, 48, or 100/110 VDC
Models with built-in CR circuits MY4Z-CR 100/110 or 200/220 VAC 110/120 or 220/240 VAC
Models with built-in CR circuits and
operation indicators
MY4ZN-CR 100/110 or 200/220 VAC 110/120 or 220/240 VAC
Note: 1. Ask your OMRON representative for details on the time required to deliver made-to-order products.
2. Ask your OMRON representative for details on product specifications and the ability to manufacture products
with voltages other than the above coil specifications.
3. The above models and specifications are new versions in the MY Series.

Miniature Power Relays with Latching Levers: MY(S)

Be sure to clearly indicate the rated voltage and add “(S)” when you place your order.
Example: MY2IN 110/110 VAC (S)

Classification
Contact
configuration
Model Rated voltage (V)
Standard products Made-to-order items
Models with built-in operation
indicators
2 MY2IN (S) --- 100/110 or 200/220 VAC
12, 24, or 48 VDC ---
4 MY4IN (S) --- 100/110 or 200/220 VAC
12, 24, or 48 VDC ---
4 bifurcated MY4ZIN (S) --- 100/110 or 200/220 VAC
--- 12, 24, or 48 VDC
Models with built-in diode for
coil surge absorption
2 MY2IN-D2 (S) 12 or 24 VDC 48 VDC
4 MY4IN-D2 (S) 24 VDC 12 or 48 VDC
4 bifurcated MY4ZIN-D2 (S) 24 VDC 12 or 48 VDC
Models with built-in CR circuit
for coil surge absorption
4 MY4IN-CR (S) --- 100/110 or 200/220 VAC
4 bifurcated MY4ZIN-CR (S) --- 100/110 or 200/220 VAC
Note: 1. Ask your OMRON representative for details on the time required to deliver made-to-order products.
2. Ask your OMRON representative for details on product specifications and the ability to manufacture products
with voltages other than the above coil specifications.

Relays with PCB Terminals: MY[]-02

When your order, specify the rated voltage.

Number
of poles
Classification Model Rated voltage (V)
Standard products Made-to-order items
2 poles Models with single
contacts
MY2-02 100/110, 200/220, or 200/240 VAC 12, 24, 100, or 110/120 VAC
12, 24 or 48 VDC 100/110 VDC
3 poles Models with single
contacts
MY3-02 100/110 or 200/220 VAC 12, 24, 110/120, or 220/240 VAC
24 VDC 12, 48, or 100/110 VDC
4 poles Models with single
contacts
MY4-02 100/110 or 200/220 VAC 12, 24, 110/120, or 220/240 VAC
12, 24 or 100/110 VDC 48 VDC
Bifurcated contacts MY4Z-02 --- 100/110, 110/120, or 200/220 VAC
100/110 VDC 12, 24, or 48 VDC
Note: 1. Ask your OMRON representative for details on the time required to deliver made-to-order products.
2. Ask your OMRON representative for details on product specifications and the ability to manufacture products
with voltages other than the above coil specifications.

Case-surface-mounting Relays: MY[]F

When your order, specify the rated voltage.

Number
of poles
Classification Model Rated voltage (V)
Standard products Made-to-order items
2 poles Models with single contacts MY2F 24, 110/110, 100/120 or 200/220 VAC 220/240 VAC
12 or 24 VDC 48 or 100/110 VDC
3 poles Models with single contacts MY3F 100/110 VAC 24 or 200/220 VAC
--- 24 or 100/110 VDC
4 poles Models with single contacts MY4F 100/110 or 200/220 VAC 24 or 110/120 VAC
12 or 24 VDC 48 or 100/110 VDC
Bifurcated contacts MY4ZF 200/220 VAC ---
--- 12 or 24 VDC
Note: 1. Ask your OMRON representative for details on the time required to deliver made-to-order products.
2. Ask your OMRON representative for details on product specifications and the ability to manufacture products
with voltages other than the above coil specifications.

Miniature Power Relays: MY4Z-CBG

When your order, specify the rated voltage.

Classification
Model Rated voltage (V)
Standard products Made-to-order items
Standard models MY4Z-CBG 100/110 or 200/220 VAC 110/120 VAC
24 or 100/110 VDC 12 or 48 VDC
Models with built-in operation indicators MY4ZN-CBG --- 100/110 or 200/220 VAC
--- 24 VDC
Note: Ask your OMRON representative for details on the time required to deliver made-to-order products.

Plastic Sealed Relays: MYQ

Relays with Plug-in or Soldered Terminals

When your order, specify the rated voltage.

Type
4 poles
Classification Model Rated voltage (V)
Models with single
contacts
Standard models MYQ4 100/110, 110/120, 200/220, or 220/240 VAC
24 VDC
Models with builtin
operation indicators
MYQ4N 24, 100/110, 110/120, 200/220, or 220/240 VAC
12, 24, 48, or 100/110 VDC
Bifurcated contacts Standard models MYQ4Z 100/110, 110/120, or 200/220 VAC
12 or 24 VDC

Relays with PCB Terminals

Type 4 poles
Classification Model Rated voltage (V)
Models with single contacts MYQ4-02 50, 200/220, or 220/240 VAC
24 VDC
Bifurcated contacts MYQ4Z-02 100/110 VAC
24 or 48 VDC

Latching Relays: MYK

When your order, specify the rated voltage.

Relays with Plug-in or Soldered Terminals

Number of poles 2 poles
Classification Model Rated voltage (V)
Standard models MY2K 12 VAC
24 VAC
100 VAC
100/110 VAC
12 VDC
24 VDC
48 VDC

Relays with PCB Terminals

Number of poles 2 poles
Classification Model Rated voltage (V)
Standard models MY2K-02 24 VAC
100 VAC
12 VDC
24 VDC

Hermetically Sealed Relays: MYH

When your order, specify the rated voltage.

Relays with Plug-in or Soldered Terminals

Type 4 poles
Classification Model Rated voltage (V)
Models with single contacts MY4H 24, 100/110, or 110/120 VAC
12, 24, 48, or 100/110 VDC
Bifurcated contacts MY4ZH 24, 100/110, or 110/120 VAC
12, 24, 48, or 100/110 VDC

Relays with PCB Terminals

Type 4 poles
Classification Model Rated voltage (V)
Models with single contacts MY4H-0 110/120 VAC
24 VDC
Bifurcated contacts MY4ZH-0 24 or 100/110 VDC

Options (Order Separately)

Connection Socket and Mounting Bracket Selection Table

(The possible combinations of models with plug-in terminals and sockets)

Connecting method
Front-mounting Sockets (PYF[])
Mounting method Track or screw mounting Screw
mounting
only
Track or
screw mounting
Terminal Type Solder terminals Push-In Plus
TerminalBlock *3
Screw
terminal
size: M3
Screw terminal
size: M3
(finger protection
structure) *2
Screw terminal size:
M3.5
Number
of pins
(Sold separately: Hold-down Clips) *1 With
Release Lever
8 MY2[]
(except for
MY2K[] and
MY2Z[]-CR)
PYF08A
(PYC-A1)
PYF08A-E
(PYC-A1)
--- PYF08M
(PYC-P)
PYF-08-PU
MY2I(S)
*5
PYF08A
(PYC-E1)
PYF08A-E
(PYC-E1)
MY2Z[]-CR
*6
PYF08A
(Y92H-3)
PYF08A-E
(Y92H-3)
---
11 MY3[] PYF11A
(PYC-A1)
--- --- --- ---
14 MY4[]
MY4H
MYQ4
MY4(S)
MY2K
PYF14A
(PYC-A1)
PYF14A-E
(PYC-A1)
PYF14T
(PYC-A1)
--- PYF-14-PU
Connecting method Back-mounting Sockets (PY[])
Mounting method
Terminal Type Solder terminals Wrapping terminals Relays with
PCB
Terminals
*4
Terminal length:
25 mm
Terminal length:
20 mm
Number
of pins
Without
Mounting
Brackets *1
With
Mounting
Brackets
Without
Mounting
Brackets *1
With
Mounting
Brackets
Without
Mounting
Brackets *1
With
Mounting
Brackets
(Sold
separately:
Hold-down
Clips) *1
8 MY2[]
(except for
MY2K[] and
MY2Z[]-CR)
PY08
(PYC-P)
PY08-Y1 PY08QN
(PYC-P)
PY08QN-Y1 PY08QN2
(PYC-P)
PY08QN2-Y1 PY08-02
(PYC-P)
MY2I(S)
*5
MY2Z[]-CR
*6
PY08
(PYC-1)
PY08-Y3 PY08QN
(PYC-1)
--- PY08QN2
(PYC-1)
--- PY08-02
(PYC-1)
11 MY3[] PY11
(PYC-P)
PY11-Y1 PY11QN
(PYC-P)
PY11QN-Y1 PY11QN2
(PYC-P)
PY11QN2-Y1 PY11-02
(PYC-P)
14 MY4[]
MY4H
MYQ4
MY4(S)
MY2K
PY14
(PYC-P)
PY14-Y1 PY14QN
(PYC-P)
PY14QN-Y1 PY14QN2
(PYC-P)
PY14QN2-Y1 PY14-02
(PYC-P)
Note: Refer to Common Socket and DIN Track Products for the external dimensions of the Socket Relays and details on Hold-down Clips.
*1. The information in parentheses is the model number of the applicable Mounting Bracket. Mounting Brackets are sold in sets of two. However, the PYC-P is just one Mounting Bracket.
*2. The PYF[]A-E has a terminal cover with finger protection. The Socket and Terminal Cover are integrated into one unit. Round terminals cannot be used. Use forked terminals or ferrules instead.
*3. A Push-In Plus Terminal Block Socket functions as a release lever to hold or remove a Relay. Refer to PYF-[][]-PU/P2RF-[][]-PU for details.
*4. If an MY[]I(S) Relay with a Latching Lever is used in combination with a PY[]-02 Socket for Relays with PCB Terminal Socket and PYC-P Mounting Brackets, the lever will not operate.
*5. We recommends using the PYC-E1 Mounting Bracket for a MY2I(S) Relay with Latching Lever. (If the PYC-A1 is used with the MY2I(S), the latching lever will be blocked by the Mounting Bracket and the lever will not operate.)
*6. The Mounting Brackets are applicable for Relays with a height of 36 mm or less. If the Relay height is greater than 53 mm, use Y92H-3 for the Front-mounting Socket and PYC-1 for the Back-mounting Socket. (The Y92H-3 is a set of two Brackets and the PYC-1 is just one Bracket.)

Socket Mounting Plate (t = 1.6) (Unit: mm)

Use a Socket Mounting Plate to mount multiple connection Back-mounting Sockets in a row.
Type For mounting
1 Socket
For mounting
8 Sockets
For mounting
36 Sockets
Item Applicable Sockets
Without
protective
bracket
PY08, PY08QN(2), PY11, PY11QN(2),
PY14, and PY14QN(2)
PYP-1 PYP-18 PYP-36
With
protective
bracket
PY08-Y1, PY08QN(2)-Y1, PY11-Y1,
PY11QN(2)-Y1, PY14-Y1, and PY14QN(2)-Y1
The minimum order for the PYP-1 is 10 pieces.
Note: You can cut the PYP-18 and PYP-36 to any required length.

Miniature Power Relays: MY2

Ratings

Operating Coils (Standard Models)

Item Rated current
(mA)
Coil
resist-
ance
(Ω)
Coil inductance (H) Must-
operate
voltage
(V)
Must-
release
voltage
(V)
Maximum
voltage
(V)
Power
con-
sumption
(VA, W)
Rated
voltage (V)
50 Hz 60 Hz Armature
OFF
Armature
ON
AC 12 106.5 91 46 0.17 0.33 80% max.
*1
30% min.
*2
110% of
rated
voltage
Approx. 0.9
to 1.3
(at 60 Hz)
24 53.8 46 180 0.69 1.3
100/110 11.7/12.9 10/11 3,750 14.54 24.6
110/120 9.9/10.8 8.4/9.2 4,430 19.2 32.1
200/220 6.2/6.8 5.3/5.8 12,950 54.75 94.07
220/240 4.8/5.3 4.2/4.6 18,790 83.5 136.4
DC 12 72.7 165 0.73 1.37 10% min.
*2
Approx. 0.9
24 36.3 662 3.2 5.72
48 17.6 2,725 10.6 21.0
100/110 8.7/9.6 11,440 45.6 86.2
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/-20%
for the AC rated current and ±15% for the DC coil resistance.
2. The AC coil resistance and inductance values are reference values only (at 60 Hz).
3. Operating characteristics were measured at a coil temperature of 23°C.
4. The maximum voltage capacity was measured at an ambient temperature of 23°C.
*1. There is variation between products, but actual values are 80% max.
To ensure operation, apply at least 80% of the rated value (at a coil temperature of +23° C).
*2. There is variation between products, but actual values are 30% minimum for AC and 10% minimum for DC. To
ensure release, use a value that is lower than the specified value.

Contact Ratings

Load Resistive load Inductive load (cos φ = 0.4, L/R = 7 ms)
Rated load 5 A at 220 VAC
5 A at 24 VDC
2 A at 220 VAC
2 A at 24 VDC
Rated carry current 5 A
Maximum contact voltage 250 VAC, 125 VDC
Maximum contact current 5 A
Contact configuration DPDT
Contact structure Single
Contact materials Ag
Type Standard models Model with built-in operation indicator,
diode, or CR circuit
Ambient operating temperature *1 -55 to 70°C -55 to 60°C *2
Ambient operating humidity 5% to 85%
*1. With no icing or condensation.
*2. This limitation is due to the diode junction temperature and elements used.

Characteristics

Type Standard
models
Models
with
built-in
operation
indicators
Models
with
built-in
CR
circuits
Models
with
built-in
diodes
Model with
built-in
operation
indicator
and diode
Model with
built-in
operation
indicator and
CR circuit
Contact resistance *1 50 mΩ max.
Operation time *2 20 ms max.
Release time *2 20 ms max.
Maximum
operating
frequency
Mechanical 18,000 operations/h
Rated load 1,800 operations/h
Insulation resistance *3 100 MΩ min.
Dielectric
strength
Between coil and
contacts
2,000 VAC at 50/60 Hz for 1 min.
Between contacts of
different polarity
Between contacts of
the same polarity
1,000 VAC at 50/60 Hz for 1 min.
Vibration
resistance
Destruction 10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude)
Malfunction 10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude)
Shock
resistance
Destruction 1,000 m/s2
Malfunction 200 m/s2
Endurance Mechanical AC: 50,000,000 operations min.
DC: 100,000,000 operations min.
(switching frequency: 18,000 operations/h)
Electrical *4 500,000 operations min. (rated load, switching frequency: 1,800 operations/h)
Number of poles 2 poles
Failure rate P value (reference value) *5 1 mA at 5 VDC
Weight Approx. 35 g
Note: These are initial values.
*1. Measurement conditions: 1 A at 5 VDC using the voltage drop method.
*2. Measurement conditions: With rated operating power applied.
Ambient temperature condition: 23° C
*3. Measurement conditions: For 500 VDC applied to the same location as for dielectric strength measurement.
*4. Ambient temperature condition: 23°C
*5. This value was measured at a switching frequency of 120 operations per minute.

Miniature Power Relays: MY2Z

Ratings

Operating Coil (Standard Models)

Item Rated current
(mA)
Coil
resist-
ance
(Ω)
Coil inductance (H) Must-
operate
voltage
(V)
Must-
release
voltage
(V)
Maximum
voltage
(V)
Power
con-
sumption
(VA, W)
Rated
voltage (V)
50 Hz 60 Hz Armature
OFF
Armature
ON
AC 12 106.5 91 46 0.17 0.33 80% max.
*1
30% min.
*2
110% of
rated
voltage
Approx. 0.9
to 1.3
(at 60 Hz)
24 53.8 46 180 0.69 1.3
100/110 11.7/12.9 10/11 3,750 14.54 24.6
110/120 9.9/10.8 8.4/9.2 4,430 19.2 32.1
200/220 6.2/6.8 5.3/5.8 12,950 54.75 94.07
220/240 4.8/5.3 4.2/4.6 18,790 83.5 136.4
DC 12 75 160 0.73 1.37 10% min.
*2
Approx. 0.9
24 36.9 650 3.2 5.72
48 18.5 2,600 10.6 21.0
100/110 9.1/10 11,000 45.6 86.2
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/-20%
for the AC rated current and ±15% for the DC coil resistance.
2. The AC coil resistance and inductance values are reference values only (at 60 Hz).
3. Operating characteristics were measured at a coil temperature of 23°C.
4. The maximum voltage capacity was measured at an ambient temperature of 23°C.
*1. There is variation between products, but actual values are 80% max.
To ensure operation, apply at least 80% of the rated value
*2. There is variation between products, but actual values are 30% minimum for AC and 10% minimum for DC. To
ensure release, use a value that is lower than the specified value.

Contact Ratings

Load Resistive load Inductive load (cos φ = 0.4, L/R = 7 ms)
Rated load 5 A at 220 VAC
5 A at 24 VDC
2 A at 220 VAC
2 A at 24 VDC
Rated carry current 5 A
Maximum contact voltage 250 VAC, 125 VDC
Maximum contact current 5 A
Contact configuration DPDT
Contact structure Bifurcated
Contact materials Au plating + Ag
Type Standard models Model with built-in operation indicator,
diode, or CR circuit
Ambient operating temperature *1 -55 to 70°C -55 to 60°C *2
Ambient operating humidity 5% to 85%
*1. With no icing or condensation.
*2. This limitation is due to the diode junction temperature and elements used.

Characteristics

Type Standard
models
Models
with
built-in
operation
indicators
Models
with
built-in
diodes
Model with
built-in
operation
indicator
and diode
Models
with
built-in
CR circuits
Models with
built-in CR
circuits and
operation
indicators
Contact resistance *1 50 mΩ max.
Operation time *2 20 ms max.
Release time *2 20 ms max.
Maximum
operating
frequency
Mechanical 18,000 operations/h
Rated load 1,800 operations/h
Insulation resistance *3 100 MΩ min.
Dielectric
strength
Between coil and
contacts
2,000 VAC at 50/60 Hz for 1 min.
Between contacts of
different polarity
Between contacts of
the same polarity
1,000 VAC at 50/60 Hz for 1 min.
Vibration
resistance
Destruction 10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude)
Malfunction 10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude)
Shock
resistance
Destruction 1,000 m/s2
Malfunction 200 m/s2
Endurance Mechanical 50,000,000 operations min. (operating frequency: 18,000 operations/h)
Electrical *4 200,000 operations min. (rated load, switching frequency: 1,800 operations/h)
Number of poles 2 poles
Failure rate P value (reference value) *5 100 μA at 1 VDC
Weight Approx. 35 g
Note: These are initial values.
*1. Measurement conditions: 1 A at 5 VDC using the voltage drop method.
*2. Measurement conditions: With rated operating power applied.
Ambient temperature condition: 23° C
*3. Measurement conditions: For 500 VDC applied to the same location as for dielectric strength measurement.
*4. Ambient temperature condition: 23°C
*5. This value was measured at a switching frequency of 120 operations per minute.

Miniature Power Relays: MY3

Ratings

Operating Coil (Standard Models)

Item Rated current
(mA)
Coil
resist-
ance
(Ω)
Coil inductance (H) Must-
operate
voltage
(V)
Must-
release
voltage
(V)
Maximum
voltage
(V)
Power
con-
sumption
(VA, W)
Rated
voltage (V)
50 Hz 60 Hz Armature
OFF
Armature
ON
AC 12 106.5 91 46 0.17 0.33 80% max.
*1
30% min.
*2
110% of
rated
voltage
Approx. 0.9
to 1.3
(at 60 Hz)
24 53.8 46 180 0.69 1.3
100/110 11.7/12.9 10/11 3,750 14.54 24.6
110/120 9.9/10.8 8.4/9.2 4,430 19.2 32.1
200/220 6.2/6.8 5.3/5.8 12,950 54.75 94.07
220/240 4.8/5.3 4.2/4.6 18,790 83.5 136.4
DC 12 75 160 0.73 1.37 10% min.
*2
Approx. 0.9
24 36.9 650 3.2 5.72
48 18.5 2,600 10.6 21.0
100/110 9.1/10 11,000 45.6 86.2
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/-20%
for the AC rated current and ±15% for the DC coil resistance.
2. The AC coil resistance and inductance values are reference values only (at 60 Hz).
3. Operating characteristics were measured at a coil temperature of 23°C.
4. The maximum voltage capacity was measured at an ambient temperature of 23°C.
*1. There is variation between products, but actual values are 80% max.
To ensure operation, apply at least 80% of the rated value
*2. There is variation between products, but actual values are 30% minimum for AC and 10% minimum for DC. To
ensure release, use a value that is lower than the specified value.

Contact Ratings

Load Resistive load Inductive load (cos φ = 0.4, L/R = 7 ms)
Rated load 5 A at 220 VAC
5 A at 24 VDC
2 A at 220 VAC
2 A at 24 VDC
Rated carry current 5 A
Maximum contact voltage 250 VAC, 125 VDC
Maximum contact current 5 A
Contact configuration 3PDT
Contact structure Single
Contact materials Ag
Type Standard models Operation indicator and diode
Ambient operating temperature *1 -55 to 70°C -55 to 60°C *2
Ambient operating humidity 5% to 85%
*1. With no icing or condensation.
*2. This limitation is due to the diode junction temperature and elements used.

Characteristics

Type Standard
models
Models with built-in
operation indicators
Models with
built-in diodes
Model with built-in
operation indicator
and diode
Contact resistance *1 50 mΩ max.
Operation time *2 20 ms max.
Release time *2 20 ms max.
Maximum
operating
frequency
Mechanical 18,000 operations/h
Rated load 1,800 operations/h
Insulation resistance *3 100 MΩ min.
Dielectric
strength
Between coil and
contacts
2,000 VAC at 50/60 Hz for 1 min.
Between contacts of
different polarity
Between contacts of
the same polarity
1,000 VAC at 50/60 Hz for 1 min.
Vibration
resistance
Destruction 10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude)
Malfunction 10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude)
Shock
resistance
Destruction 1,000 m/s2
Malfunction 200 m/s2
Endurance Mechanical AC: 50,000,000 operations min.
DC: 100,000,000 operations min.
(switching frequency: 18,000 operations/h)
Electrical *4 500,000 operations min. (rated load, switching frequency: 1,800 operations/h)
Number of poles 3 poles
Failure rate P value (reference value) *5 1 mA at 5 VDC
Weight Approx. 35 g
Note: These are initial values.
*1. Measurement conditions: 1 A at 5 VDC using the voltage drop method
*2. Measurement conditions: With rated operating power applied.
Ambient temperature condition: 23° C
*3. Measurement conditions: For 500 VDC applied to the same location as for dielectric strength measurement.
*4. Ambient temperature condition: 23°C
*5. This value was measured at a switching frequency of 120 operations per minute.

Miniature Power Relays: MY4

Ratings

Operating Coil (Standard Models)

Item Rated current
(mA)
Coil
resist-
ance
(Ω)
Coil inductance (H) Must-
operate
voltage
(V)
Must-
release
voltage
(V)
Maximum
voltage
(V)
Power
con-
sumption
(VA, W)
Rated
voltage (V)
50 Hz 60 Hz Armature
OFF
Armature
ON
AC 12 106.5 91 46 0.17 0.33 80% max.
*1
30% min.
*2
110% of
rated
voltage
Approx. 0.9
to 1.3
(at 60 Hz)
24 53.8 46 180 0.69 1.3
100/110 11.7/12.9 10/11 3,750 14.54 24.6
110/120 9.9/10.8 8.4/9.2 4,430 19.2 32.1
200/220 6.2/6.8 5.3/5.8 12,950 54.75 94.07
220/240 4.8/5.3 4.2/4.6 18,790 83.5 136.4
DC 12 72.7 165 0.73 1.37 10% min.
*2
Approx. 0.9
24 36.3 662 3.2 5.72
48 17.6 2,725 10.6 21.0
100/110 8.7/9.6 11,440 45.6 86.2
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/-20%
for the AC rated current and ±15% for the DC coil resistance.
2. The AC coil resistance and inductance values are reference values only (at 60 Hz).
3. Operating characteristics were measured at a coil temperature of 23°C.
4. The maximum voltage capacity was measured at an ambient temperature of 23°C.
*1. There is variation between products, but actual values are 80% max.
To ensure operation, apply at least 80% of the rated value
*2. There is variation between products, but actual values are 30% minimum for AC and 10% minimum for DC. To
ensure release, use a value that is lower than the specified value.

Contact Ratings

Load Resistive load Inductive load (cos φ = 0.4, L/R = 7 ms)
Rated load 3 A at 220 VAC
3 A at 24 VDC
0.8 A at 220 VAC
1.5 A at 24 VDC
Rated carry current 3 A
Maximum contact voltage 250 VAC, 125 VDC
Maximum contact current 3 A
Contact configuration 4PDT
Contact structure Single
Contact materials Au cladding + Ag alloy
Type Standard models Model with built-in operation indicator,
diode, or CR circuit
Ambient operating temperature *1 -55 to 70°C -55 to 60°C *2
Ambient operating humidity 5% to 85%
*1. With no icing or condensation.
*2. This limitation is due to the diode junction temperature and elements used.

Characteristics

Type Standard
models
Models
with
built-in
operation
indicators
Models
with
built-in
CR
circuits
Models
with
built-in
diodes
Model with
built-in
operation
indicator
and diode
Model with
built-in
operation
indicator and
CR circuit
Contact resistance *1 50 mΩ max.
Operation time *2 20 ms max.
Release time *2 20 ms max.
Maximum
operating
frequency
Mechanical 18,000 operations/h
Rated load 1,800 operations/h
Insulation resistance *3 100 MΩ min.
Dielectric
strength
Between coil and
contacts
2,000 VAC at 50/60 Hz for 1 min.
Between contacts of
different polarity
Between contacts of
the same polarity
1,000 VAC at 50/60 Hz for 1 min.
Vibration
resistance
Destruction 10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude)
Malfunction 10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude)
Shock
resistance
Destruction 1,000 m/s2
Malfunction 200 m/s2
Endurance Mechanical AC: 50,000,000 operations min.
DC: 100,000,000 operations min.
(switching frequency:: 18,000 operations/h)
Electrical *4 200,000 operations min. (rated load, switching frequency: 1,800 operations/h)
Number of poles 4 poles
Failure rate P value (reference value) *5 1 mA at 1 VDC
Weight Approx. 35 g
Note: These are initial values.
*1. Measurement conditions: 1 A at 5 VDC using the voltage drop method
*2. Measurement conditions: With rated operating power applied.
Ambient temperature condition: 23° C
*3. Measurement conditions: For 500 VDC applied to the same location as for dielectric strength measurement.
*4. Ambient temperature condition: 23° C
*5. This value was measured at a switching frequency of 120 operations per minute.

Miniature Power Relays: MY4Z

Ratings

Operating Coil (Standard Models)

Item Rated current
(mA)
Coil
resist-
ance
(Ω)
Coil inductance (H) Must-
operate
voltage
(V)
Must-
release
voltage
(V)
Maximum
voltage
(V)
Power
con-
sumption
(VA, W)
Rated
voltage (V)
50 Hz 60 Hz Armature
OFF
Armature
ON
AC 12 106.5 91 46 0.17 0.33 80% max.
*1
30% min.
*2
110% of
rated
voltage
Approx. 0.9
to 1.3
(at 60 Hz)
24 53.8 46 180 0.69 1.3
100/110 11.7/12.9 10/11 3,750 14.54 24.6
110/120 9.9/10.8 8.4/9.2 4,430 19.2 32.1
200/220 6.2/6.8 5.3/5.8 12,950 54.75 94.07
220/240 4.8/5.3 4.2/4.6 18,790 83.5 136.4
DC 12 72.7 165 0.73 1.37 10% min.
*2
Approx. 0.9
24 36.3 662 3.2 5.72
48 17.6 2,725 10.6 21.0
100/110 8.7/9.6 11,440 45.6 86.2
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/-20%
for the AC rated current and ±15% for the DC coil resistance.
2. The AC coil resistance and inductance values are reference values only (at 60 Hz).
3. Operating characteristics were measured at a coil temperature of 23°C.
4. The maximum voltage capacity was measured at an ambient temperature of 23°C.
*1. There is variation between products, but actual values are 80% max.
To ensure operation, apply at least 80% of the rated value
*2. There is variation between products, but actual values are 30% minimum for AC and 10% minimum for DC. To
ensure release, use a value that is lower than the specified value.

Contact Ratings

Load Resistive load Inductive load (cos φ = 0.4, L/R = 7 ms)
Rated load 3 A at 220 VAC
3 A at 24 VDC
0.8 A at 220 VAC
1.5 A at 24 VDC
Rated carry current 3 A
Maximum contact voltage 250 VAC, 125 VDC
Maximum contact current 3 A
Contact configuration 4PDT
Contact structure Bifurcated
Contact materials Au cladding + Ag alloy
Type Standard models Model with built-in operation indicator,
diode, or CR circuit
Ambient operating temperature *1 -55 to 70°C -55 to 60°C
Ambient operating humidity 5% to 85%
*1. With no icing or condensation.
*2. This limitation is due to the diode junction temperature and elements used.

Characteristics

Type Standard
models
Models
with
built-in
operation
indicators
Models
with
built-in
CR
circuits
Models
with
built-in
diodes
Model with
built-in
operation
indicator and
diode
Model with
built-in
operation
indicator and
CR circuit
Contact resistance *1 50 mΩ max.
Operation time *2 20 ms max.
Release time *2 20 ms max.
Maximum
operating
frequency
Mechanical 18,000 operations/h
Rated load 1,800 operations/h
Insulation resistance *3 100 MΩ min.
Dielectric
strength
Between coil and
contacts
2,000 VAC at 50/60 Hz for 1 min.
Between contacts of
different polarity
Between contacts of
the same polarity
1,000 VAC at 50/60 Hz for 1 min.
Vibration
resistance
Destruction 10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude)
Malfunction 10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude)
Shock
resistance
Destruction 1,000 m/s2
Malfunction 200 m/s2
Endurance Mechanical 20,000,000 operations min. (switching frequency: 18,000 operations/h)
Electrical *4 100,000 operations min. (rated load, switching frequency: 1,800 operations/h)
Number of poles 4 poles
Failure rate P value (reference value) *5 100 μA at 1 VDC
Weight Approx. 35 g
Note: These are initial values.
*1. Measurement conditions: 1 A at 5 VDC using the voltage drop method
*2. Measurement conditions: With rated operating power applied.
Ambient temperature condition: 23° C
*3. Measurement conditions: For 500 VDC applied to the same location as for dielectric strength measurement.
*4. Ambient temperature condition: 23° C
*5. This value was measured at a switching frequency of 120 operations per minute.

Miniature Power Relays with Latching Levers: MY(S)

Ratings

Operating Coil

Item Rated current
(mA)
Coil
resist-
ance
(Ω)
Coil inductance (H) Must-
operate
voltage
(V)
Must-
release
voltage
(V)
Maximum
voltage
(V)
Power
con-
sumption
(VA, W)
Rated
voltage (V)
50 Hz 60 Hz Armature
OFF
Armature
ON
AC 100/110 11.7/12.9 10/11 3,750 14.54 24.6 80% max.
*1
30% min.
*2
110% of
rated
voltage
Approx. 0.9 to
1.3 (at 60 Hz)
200/220 6.2/6.8 5.3/5.8 12,950 54.75 94.07
DC 12 75 160 0.73 1.37 10% min.
*2
Approx. 0.9
24 37.7 636 3.2 5.72
48 18.8 2,560 10.6 21
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/-20%
for the AC rated current and ±15% for the DC coil resistance.
2. The AC coil resistance and inductance values are reference values only (at 60 Hz).
3. Operating characteristics were measured at a coil temperature of 23°C.
4. The maximum voltage capacity was measured at an ambient temperature of 23°C.
*1. There is variation between products, but actual values are 80% max.
To ensure operation, apply at least 80% of the rated value.
*2. There is variation between products, but actual values are 30% minimum for AC and 10% minimum for DC. To
ensure release, use a value that is lower than the specified value.

Contact Ratings

Number of poles 2 poles
Load Resistive load (cos φ = 1) Inductive load (cos φ = 0.4, L/R = 7 ms)
Rated load 5 A at 250 VAC
5 A at 30 VDC
2 A at 250 VAC
2 A at 30 VDC
Rated carry current 10 A *
Maximum contact voltage 250 VAC, 125 VDC
Maximum contact current 10 A
Contact configuration Single
Contact materials Ag
Number of poles 4 poles 4 poles (bifurcated)
Load Resistive load
(cos φ = 1)
Inductive load
(cos φ = 0.4,
L/R = 7 ms)
Resistive load
(cos φ = 1)
Inductive load
(cos φ = 0.4,
L/R = 7 ms)
Rated load 3 A at 250 VAC
3 A at 30 VDC
0.8 A at 250 VAC
1.5 A at 30 VDC
3 A at 250 VAC
3 A at 30 VDC
0.8 A at 250 VAC
1.5 A at 30 VDC
Rated carry current 5 A *
Maximum contact voltage 250 VAC, 125 VDC
Maximum contact current 5 A
Contact configuration Single Bifurcated
Contact materials Au cladding + Ag alloy Au cladding + Ag alloy
* If you use a Socket, do not exceed the rated carry current of the Socket.

Type
Model with built-in operation indicator, diode, or CR circuit
Ambient operating temperature *1 -55 to 70°C*2
Ambient operating humidity 5% to 85%
*1. With no icing or condensation.
*2. This limitation is due to the diode junction temperature and elements used.

Characteristics

Type 2 poles 4 poles 4 poles (bifurcated)
Contact resistance *1 100 mΩ max.
Operation time *2 20 ms max.
Release time *2 20 ms max.
Maximum
operating
frequency
Mechanical 18,000 operations/h
Rated load 1,800 operations/h
Insulation resistance *3 1,000 MΩ min.
Dielectric
strength
Between coil and
contacts
2,000 VAC at 50/60 Hz for 1 min.
Between contacts of
different polarity
Between contacts of
the same polarity
1,000 VAC at 50/60 Hz for 1 min.
Vibration
resistance
Destruction 10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude)
Malfunction 10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude)
Shock
resistance
Destruction 1,000 m/s2
Malfunction 200 m/s2
Endurance Mechanical AC: 50,000,000 operations min.,
DC: 100,000,000 operations min.
(switching frequency: 18,000 operations/h)
20,000,000 operations
min. (switching frequency:
18,000 operations/h)
Electrical *4 500,000 operations min.
(rated load, switching
frequency: 1,800
operations/h)
200,000 operations min.
(rated load, switching
frequency: 1,800
operations/h)
100,000 operations min.
(rated load, switching
frequency: 1,800
operations/h)
Failure rate P value
(reference value) *5
1 mA at 5 VDC 1 mA at 1 VDC 100 μA at 1 VDC
Weight Approx. 35 g
Note: These are initial values.
*1. Measurement conditions: 1 A at 5 VDC using the voltage drop method
*2. Measurement conditions: When rated operating power is applied and ambient temperature is 23° C
*3. Measurement conditions: For 500 VDC applied to the same location as for dielectric strength measurement.
*4. Ambient temperature condition: 23° C
*5. This value was measured at a switching frequency of 120 operations per minute.

Relays with PCB Terminals: MY[]-02

Ratings

Operating Coil (Standard Models)

Item Rated current
(mA)
Coil
resist-
ance
(Ω)
Coil inductance (H) Must-
operate
voltage
(V)
Must-
release
voltage
(V)
Maximum
voltage
(V)
Power
con-
sumption
(VA, W)
Rated
voltage (V)
50 Hz 60 Hz Armature
OFF
Armature
ON
AC 12 106.5 91 46 0.17 0.33 80% max.
*1
30% min.
*2
110% of
rated
voltage
Approx. 0.9
to 1.3
(at 60 Hz)
24 53.8 46 180 0.69 1.3
100/110 11.7/12.9 10/11 3,750 14.54 24.6
110/120 9.9/10.8 8.4/9.2 4,430 19.2 32.1
200/220 6.2/6.8 5.3/5.8 12,950 54.75 94.07
220/240 4.8/5.3 4.2/4.6 18,790 83.5 136.4
DC 12 75 160 0.73 1.37 10% min.
*2
Approx. 0.9
24 36.9 650 3.2 5.72
48 18.5 2,600 10.6 21.0
100/110 9.1/10 11,000 45.6 86.2
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/-20%
for the AC rated current and ±15% for the DC coil resistance.
2. The AC coil resistance and inductance values are reference values only (at 60 Hz).
3. Operating characteristics were measured at a coil temperature of 23°C.
4. The maximum voltage capacity was measured at an ambient temperature of 23°C.
*1. There is variation between products, but actual values are 80% max.
To ensure operation, apply at least 80% of the rated value.
*2. There is variation between products, but actual values are 30% minimum for AC and 10% minimum for DC. To
ensure release, use a value that is lower than the specified value.

Contact Ratings

Number of poles 2 or 3 poles
Load Resistive load Inductive load (cos φ= 0.4, L/R = 7 ms)
Rated load 5 A at 220 VAC
5 A at 24 VDC
2 A at 220 VAC
2 A at 24 VDC
Rated carry current 5 A
Maximum contact voltage 250 VAC, 125 VDC
Maximum contact current 5 A
Contact configuration DPDT, 3PDT
Contact structure Single
Contact materials Ag
Number of poles 4 poles 4 poles, bifurcated contacts
Load Resistive load Inductive load
(cos φ= 0.4,
L/R = 7 ms)
Resistive load Inductive load
(cos φ= 0.4,
L/R = 7 ms)
Rated load 3 A at 220 VAC
3 A at 24 VDC
0.8 A at 220 VAC
1.5 A at 24 VDC
3 A at 220 VAC
3 A at 24 VDC
0.8 A at 220 VAC
1.5 A at 24 VDC
Rated carry current 3 A 3 A
Maximum contact voltage 250 VAC, 125 VDC 250 VAC, 125 VDC
Maximum contact current 3 A 3 A
Contact configuration 4PDT 4PDT
Contact structure Single Bifurcated
Contact materials Au plating + Ag Au plating + Ag
Type Standard models
Ambient operating temperature * -55 to 70°C
Ambient operating humidity 5% to 85%
* With no icing or condensation.

Characteristics

Number of poles 2 or 3 poles 4 poles 4 poles,
bifurcated contacts
Contact resistance *1 50 mΩ max.
Operation time *2 20 ms max.
Release time *2 20 ms max.
Maximum
operating
frequency
Mechanical 18,000 operations/h
Rated load 1,800 operations/h
Insulation resistance *3 100 MΩ min.
Dielectric
strength
Between coil and
contacts
2,000 VAC at 50/60 Hz for 1 min.
Between contacts of
different polarity
Between contacts of
the same polarity
1,000 VAC at 50/60 Hz for 1 min.
Vibration
resistance
Destruction 10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude)
Malfunction 10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude)
Shock
resistance
Destruction 1,000 m/s2
Malfunction 200 m/s2
Endurance Mechanical AC: 50,000,000 operations min.
DC: 100,000,000 operations min.
(switching frequency: 18,000 operations/h)
AC: 20,000,000 operations
min. (switching frequency:
18,000 operations/h)
Electrical *4 500,000 operations min.
(rated load, switching
frequency: 1,800
operations/h)
200,000 operations min.
(rated load, switching
frequency: 1,800
operations/h)
100,000 operations min.
(rated load, switching
frequency: 1,800
operations/h)
Number of poles 2 or 3 poles 4 poles 4 poles, bifurcated contacts
Failure rate P value
(reference value) *5
1 mA at 5 VDC 1 mA at 1 VDC 100 μA at 1 VDC
Weight Approx. 35 g
Note: These are initial values.
*1. Measurement conditions: 1 A at 5 VDC using the voltage drop method
*2. Measurement conditions: With rated operating power applied.
Ambient temperature condition: 23° C
*3. Measurement conditions: For 500 VDC applied to the same location as for dielectric strength measurement.
*4. Ambient temperature condition: 23° C
*5. This value was measured at a switching frequency of 120 operations per minute.

Case-surface-mounting Relays: MY[]F

Ratings

Operating Coil (Standard Models)

Item Rated current
(mA)
Coil
resist-
ance
(Ω)
Coil inductance (H) Must-
operate
voltage
(V)
Must-
release
voltage
(V)
Maximum
voltage
(V)
Power
con-
sumption
(VA, W)
Rated
voltage (V)
50 Hz 60 Hz Armature
OFF
Armature
ON
AC 24 53.8 46 180 0.69 1.3 80% max.
*1
30% min.
*2
110% of
rated
voltage
Approx. 0.9
to 1.3
(at 60 Hz)
100/110 11.7/12.9 10/11 3,750 14.54 24.6
110/120 9.9/10.8 8.4/9.2 4,430 19.2 32.1
200/220 6.2/6.8 5.3/5.8 12,950 54.75 94.07
220/240 4.8/5.3 4.2/4.6 18,790 83.5 136.4
DC 12 75 160 0.73 1.37 10% min.
*2
Approx. 0.9
24 36.9 650 3.2 5.72
48 18.5 2,600 10.6 21.0
100/110 9.1/10 11,000 45.6 86.2
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/-20%
for the AC rated current and ±15% for the DC coil resistance.
2. The AC coil resistance and inductance values are reference values only (at 60 Hz).
3. Operating characteristics were measured at a coil temperature of 23°C.
4. The maximum voltage capacity was measured at an ambient temperature of 23°C.
*1. There is variation between products, but actual values are 80% max.
To ensure operation, apply at least 80% of the rated value
*2. There is variation between products, but actual values are 30% minimum for AC and 10% minimum for DC. To
ensure release, use a value that is lower than the specified value.

Contact Ratings

Number of poles 2 or 3 poles 4 poles
Load Resistive load Inductive load
(cos φ = 0.4,
L/R = 7 ms)
Resistive load Inductive load
(cos φ = 0.4,
L/R = 7 ms)
Rated load 5 A at 220 VAC
5 A at 24 VDC
2 A at 220 VAC
2 A at 24 VDC
3 A at 220 VAC
3 A at 24 VDC
0.8 A at 220 VAC
1.5 A at 24 VDC
Rated carry current 5 A 3 A
Maximum contact voltage 250 VAC, 125 VDC 250 VAC, 125 VDC
Maximum contact current 5 A 3 A
Contact configuration DPDT, 3PDT 4PDT
Contact structure Single Single
Contact materials Ag Au plating + Ag
Type Standard models
Ambient operating temperature * -55 to 70°C
Ambient operating humidity 5% to 85%
* With no icing or condensation.

Characteristics

Number of poles 2 or 3 poles 4 poles
Contact resistance *1 50 mΩ max.
Operation time *2 20 ms max.
Release time *2 20 ms max.
Maximum
operating
frequency
Mechanical 18,000 operations/h
Rated load 1,800 operations/h
Insulation resistance *3 100 MΩ min.
Dielectric
strength
Between coil and contacts 2,000 VAC at 50/60 Hz for 1 min.
Between contacts of
different polarity
Between contacts of the
same polarity
1,000 VAC at 50/60 Hz for 1 min.
Vibration
resistance
Destruction 10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude)
Malfunction 10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude)
Shock
resistance
Destruction 1,000 m/s2
Malfunction 200 m/s2
Endurance Mechanical AC: 50,000,000 operations min.
DC: 100,000,000 operations min.
(switching frequency: 18,000 operations/h)
Electrical *4 500,000 operations min.
(rated load, switching frequency:
1,800 operations/h)
200,000 operations min.
(rated load, switching frequency:
1,800 operations/h)
Number of poles 2 or 3 poles 4 poles
Failure rate P value (reference value) *5 1 mA at 5 VDC 1 mA at 1 VDC
Weight Approx. 35 g
Note: These are initial values.
*1. Measurement conditions: 1 A at 5 VDC using the voltage drop method
*2. Measurement conditions: With rated operating power applied.
Ambient temperature condition: 23° C
*3. Measurement conditions: For 500 VDC applied to the same location as for dielectric strength measurement.
*4. Ambient temperature condition: 23° C
*5. This value was measured at a switching frequency of 120 operations per minute.

Miniature Power Relays: MY4Z-CBG

Ratings

Operating Coil

Item Rated current
(mA)
Coil
resist-
ance
(Ω)
Coil inductance (H) Must-
operate
voltage
(V)
Must-
release
voltage
(V)
Maximum
voltage
(V)
Power
con-
sumption
(VA, W)
Rated
voltage (V)
50 Hz 60 Hz Armature
OFF
Armature
ON
AC 100/110 11.7/12.9 10/11 3,750 14.54 24.6 80% max.
*1
30% min.
*2
110% of
rated
voltage
Approx. 0.9
to 1.3
(at 60 Hz)
110/120 9.9/10.8 8.4/9.2 4,430 19.2 32.1
200/220 6.2/6.8 5.3/5.8 12,950 54.75 94.07
DC 12 75 160 0.73 1.37 10% min.
*2
Approx. 0.9
24 36.9 650 3.2 5.72
100/110 9.1/10 11,000 45.60 86.20
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/-20%
for the AC rated current and ±15% for the DC coil resistance.
2. The AC coil resistance and inductance values are reference values only
3. Operating characteristics were measured at a coil temperature of 23°C.
4. The maximum voltage capacity was measured at an ambient temperature of 23°C.
*1. There is variation between products, but actual values are 80% max.
To ensure operation, apply at least 80% of the rated value
*2. There is variation between products, but actual values are 30% minimum for AC and 10% minimum for DC. To
ensure release, use a value that is lower than the specified value.

Contact Ratings

Load Resistive load Inductive load (cos φ = 0.4, L/R = 7 ms)
Rated load 1 A at 220 VAC
1 A at 24 VDC
0.3 A at 220 VAC
0.5 A at 24 VDC
Rated carry current 1 A
Maximum contact voltage 250 VAC, 125 VDC
Maximum contact current 1 A 1 A
Contact structure Crossbar bifurcated
Contact materials Au cladding + AgPd

Characteristics

Contact resistance *1 100 mΩ max.
Operation time *2 20 ms max.
Release time *2 20 ms max.
Maximum
operating
frequency
Mechanical 18,000 operations/h
Electrical 1,800 operations/h
Insulation resistance *3 100 MΩ
Dielectric
strength
Between coil and
contacts
2,000 VAC at 50/60 Hz for 1 min.
Between contacts of
different polarity
Between contacts of
the same polarity
700 VAC at 50/60 Hz for 1 min.
Vibration
resistance
Destruction 10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude)
Malfunction 10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude)
Shock
resistance
Destruction 1,000 m/s2
Malfunction 200 m/s2
Endurance Mechanical 5,000,000 operations min. (operating frequency: 18,000 operations/hr)
Electrical *4 50,000 operations min. (switching frequency: 1,800 operations/h) at rated load
Failure rate P value
(reference value) *5
100 μA at 1 VDC
Ambient operating temperature .25 to 70°C (with no icing or condensation)
Ambient operating humidity 5% to 85%
Weight Approx. 35 g
Note: The above values are initial values.
*1. Measurement conditions: 1 A at 5 VDC using the voltage drop method
*2. Measurement conditions: With rated operating power applied, not including contact bounce.
Ambient temperature condition: 23° C
*3. Measurement conditions: For 500 VDC applied to the same location as for dielectric strength measurement.
*4. Ambient temperature condition: 23° C
*5. This value was measured at a switching frequency of 120 operations per minute.

Plastic Sealed Relays: MYQ

Ratings

Operating Coil

Item Rated current
(mA)
Coil
resist-
ance
(Ω)
Coil inductance (H) Must-
operate
voltage
(V)
Must-
release
voltage
(V)
Maximum
voltage
(V)
Power
con-
sumption
(VA, W)
Rated
voltage (V)
50 Hz 60 Hz Armature
OFF
Armature
ON
AC 24 53.8 46 180 0.69 1.3 80% max.
*1
30% min.
*2
110% of
rated
voltage
Approx.
0.9 to 1.3
(at 60 Hz)
100/110 11.7/12.9 10/11 3,750 14.54 24.6
110/120 9.9/10.8 8.4/9.2 4,430 19.2 32.1
200/220 6.2/6.8 5.3/5.8 12,950 54.75 91.07
220/240 4.8/5.3 4.2/4.6 18,790 83.5 136.4
DC 12 75 160 0.734 1.37 10% min.
*2
Approx. 0.9
24 36.9 650 3.2 5.72
48 18.5 2,600 10.6 21.0
100/110 9.1/10 11,000 45.6 86.0
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/-20%
for AC rated current and ±15% for DC coil resistance.
2. The AC coil resistance and coil inductance values are reference values only.
3. Operating characteristics were measured at a coil temperature of 23°C.
4. The maximum voltage capacity was measured at an ambient temperature of 23°C.
*1. There is variation between products, but actual values are 80% max.
To ensure operation, apply at least 80% of the rated value
*2. There is variation between products, but actual values are 30% minimum for AC and 10% minimum for DC. To
ensure release, use a value that is lower than the specified value.

Contact Ratings

Load Resistive load Inductive load
(cos φ = 0.4, L/R = 7 ms)
Rated load 1 A at 220 VAC, 1 A at 24 VDC 0.5 A at 220 VAC, 0.5 A at 24 VDC
Rated carry current 1 A
Maximum contact voltage 250 VAC, 125 VDC
Maximum contact current 1 A
Maximum switching capacity
(reference value)
220 VAC, 24 W 110 VAC, 12 W
Failure rate P value (reference value) Single contacts: 1 mA at 1 VDC, Bifurcated contacts: 100 μA at 1 VDC
Contact structure Single/bifurcated
Contact materials Au plating + Ag
* This value was measured at a switching frequency of 120 operations per minute.

Ambient operating temperature
-55 to 60°C *
Ambient operating humidity 5% to 85%
* With no icing or condensation.

Characteristics

Contact resistance *1 50 mΩ max.
Operation time *2 20 ms max.
Release time *2 20 ms max.
Maximum
operating
frequency
Mechanical 18,000 operations/h
Rated load 1,800 operations/h
Dielectric
strength
Between coil and
contacts
1,500 VAC at 50/60 Hz for 1 min.
Between contacts of
different polarity
1,500 VAC at 50/60 Hz for 1 min.
Between contacts of
the same polarity
1,000 VAC at 50/60 Hz for 1 min.
Insulation resistance *3 100 MΩ min.
Vibration
resistance
Destruction 10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude)
Malfunction 10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude)
Shock
resistance
Destruction 1,000 m/s2
Malfunction 200 m/s2
Endurance Mechanical AC: 50,000,000 operations (5,000,000 *4) min.,
DC: 100,000,000 operations (5,000,000 *4) min.
(switching frequency: 18,000 operations/h)
Electrical *5 200,000 operations min. (100,000 operations *4)
(rated load, switching frequency: 1,800 operations/h)
Weight Approx. 35 g
Note: The values at the left are initial values.
*1. Measurement conditions: 1 A at 5 VDC using the voltage drop method
*2. Measurement conditions: With rated operating power applied, not including contact bounce.
Ambient temperature condition: 23° C
*3. Measurement conditions: For 500 VDC applied to the same location as for dielectric strength measurement.
*4. This value is for bifurcated contacts.
*5. Ambient temperature condition: 23° C

Latching Relays: MYK

Ratings

Operating Coil

Item Set coil Reset coil Set
voltage
(V)
Reset
voltage
(V)
Maximum
voltage
(V)
Power consumption
(VA, W)
Rated
voltage (V)
Rated
current
(mA)
Coil
resist-
ance
(Ω)
Rated
current
(mA)
Coil
resist-
ance
(Ω)
Set coil Reset
coil
50 Hz 60 Hz 50 Hz 60 Hz
AC 12 57 56 72 39 38.2 130 80%
max.
80%
max.
110% max.
of rated
voltage
Approx.
0.6 to 0.9
(at 60 Hz)
Approx.
0.2 to 0.5
(at 60 Hz)
24 27.4 26.4 320 18.6 18.1 550
100 7.1 6.9 5,400 3.5 3.4 3,000
DC 12 110 110 50 235 Approx.
1.3
Approx.
0.6
24 52 470 25 940
48 27 1,800 16 3,000
Note: 1. The rated current for AC is the value measured with a DC ammeter in half-wave rectification.
2. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/-20%
for the AC rated current and ±15% for the DC coil resistance.
3. The AC coil resistance is a reference value only.
4. Operating characteristics were measured at a coil temperature of 23°C.
5. The maximum voltage capacity was measured at an ambient temperature of 23°C.

Contact Ratings

Load Resistive load Inductive load (cos φ = 0.4, L/R = 7 ms)
Rated load 3 A at 220 VAC
3 A at 24 VDC
0.8 A at 220 VAC
1.5 A at 24 VDC
Rated carry current 3 A
Maximum contact voltage 250 VAC, 125 VDC
Maximum contact current 3 A 3 A
Contact structure Single
Contact materials Au plating + Ag
Ambient operating temperature -55 to 60°C *
Ambient operating humidity 5% to 85%
* With no icing or condensation.

Characteristics

Contact resistance *1 50 mΩ max.
Set Time *2 AC: 30 ms max., DC: 15 ms max.
Minimum pulse width AC: 60 ms, DC: 30 ms
Reset Time *2 AC: 30 ms max., DC: 15 ms max.
Minimum pulse width AC: 60 ms, DC: 30 ms
Maximum
operating
frequency
Mechanical 18,000 operations/h
Rated load 1,800 operations/h
Insulation resistance *3 100 MΩ
Dielectric
strength
Between coil and
contacts
1,500 VAC at 50/60 Hz for 1 min.
Between contacts of
different polarity
Between contacts of
the same polarity
1,000 VAC at 50/60 Hz for 1 min.
Between set/
reset coils
Vibration
resistance
Destruction 10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude)
Malfunction 10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude)
Shock
resistance
Destruction 1,000 m/s2
Malfunction 200 m/s2
Endurance Mechanical 100,000,000 operations min. (switching frequency: 18,000 operations/h)
Electrical *4 200,000 operations min. (at 1,800 operations/hr, rated load)
Failure rate P value
(reference value) *5
1 mA at 1 VDC
Weight Approx. 30 g
Note: The above values are initial values.
*1. Measurement conditions: 1 A at 5 VDC using the voltage drop method
*2. Measurement conditions: With rated operating power applied, not including contact bounce.
*3. Measurement conditions: For 500 VDC applied to the same location as for dielectric strength measurement.
*4. Ambient temperature condition: 23° C
*5. This value was measured at a switching frequency of 120 operations per minute.

Hermetically Sealed Relays: MYH

Ratings

Operating Coil

Item Rated current
(mA)
Coil
resist-
ance
(Ω)
Coil inductance (H) Must-
operate
voltage
(V)
Must-
release
voltage
(V)
Maximum
voltage
(V)
Power
con-
sumption
(VA, W)
Rated
voltage (V)
50 Hz 60 Hz Armature
OFF
Armature
ON
AC 24 53.8 46 180 0.69 1.3 80% max.
*1
30% min.
*2
110% of
rated
voltage
Approx. 0.9
to 1.3
(at 60 Hz)
100/110 11.7/12.9 10/11 3,750 14.54 24.6
110/120 9.9/10.8 8.4/9.2 4,430 19.2 32.1
DC 12 75 160 0.73 1.37 10% min.
*2
Approx. 0.9
24 36.9 650 3.2 5.72
48 18.5 2,600 10.6 21.0
100/110 9.1/10 11,000 45.6 86.2
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/-20%
for the AC rated current and ±15% for the DC coil resistance.
2. The AC coil resistance and inductance values are reference values only
3. Operating characteristics were measured at a coil temperature of 23°C.
4. The maximum voltage capacity was measured at an ambient temperature of 23°C.
*1. There is variation between products, but actual values are 80% max.
To ensure operation, apply at least 80% of the rated value
*2. There is variation between products, but actual values are 30% minimum for AC and 10% minimum for DC. To
ensure release, use a value that is lower than the specified value.

Contact Ratings

Load Models with single contacts Bifurcated contacts
Resistive load Inductive load
cos φ = 0.4
L/R = 7 ms
Resistive load Inductive load
cos φ = 0.4
L/R = 7 ms
Rated load 3 A at 110 VAC
3 A at 24 VDC
0.8 A at 110 VAC
1.5 A at 24 VDC
3 A at 110 VAC
3 A at 24 VDC
0.8 A at 110 VAC
1.5 A at 24 VDC
Rated carry current 3 A 3 A
Maximum contact voltage 125 VAC, 125 VDC 125 VAC, 125 VDC
Maximum contact current 3 A 3 A
Contact structure Single Bifurcated
Contact materials Au plating + Ag
Ambient operating temperature -25 to 60°C *
Ambient operating humidity 5% to 85%
* With no icing or condensation.

Characteristics

Contact resistance *1 50 mΩ max.
Operation time *2 20 ms max.
Release time *2 20 ms max.
Maximum
operating
frequency
Mechanical 18,000 operations/h
Rated load 1,800 operations/h
Insulation resistance *4 100 MΩ min.
Dielectric
strength
Between coil and contacts 1,000 VAC at 50/60 Hz for 1 min.
(700 VAC between contacts of the same polarity.)
Between contacts of
different polarity
Vibration
resistance
Destruction 10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude)
Malfunction 10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude)
Shock
resistance
Destruction 1,000 m/s2
Malfunction 200 m/s2
Endurance Mechanical 50,000,000 operations (5,000,000 operations *4) min.
(operating frequency: 18,000 operations/h)
Electrical *5 100,000 operations (50,000 operations*4) min. rated load,
switching frequency: 1,800 operations/h)
Failure rate P value
(reference value) *6
Single contacts: 100 μA at 1 VDC
Bifurcated contacts: 100 μA at 100 mVDC
Weight Approx. 50 g
Note: The above values are initial values.
*1. Measurement conditions: 1 A at 5 VDC using the voltage drop method
*2. Measurement conditions: With rated operating power applied, not including contact bounce.
Ambient temperature condition: 23° C
*3. Measurement conditions: For 500 VDC applied to the same location as for dielectric strength measurement.
*4. This value is for bifurcated contacts.
*5. Ambient temperature condition: 23° C
*6. This value was measured at a switching frequency of 120 operations per minute.

Miniature Power Relays: MY2

MY2, MY2N, MY2-D, MY2N-D2, MY2-CR, and MY2N-CR

MY Dimensions 2

Miniature Power Relays: MY2Z

MY2Z, MY2ZN, MY2Z-D, MY2ZN-D2, MY2Z-CR, and MY2ZN-CR

MY Dimensions 4

Miniature Power Relays: MY3

MY3, MY3N, MY3-D, and MY3N-D2

MY Dimensions 6

Miniature Power Relays: MY4

MY4, MY4N, MY4-D, MY4N-D2, MY4-CR, and MY4N-CR

MY Dimensions 8

Miniature Power Relays: MY4Z

MY4Z, MY4ZN, MY4Z-D, MY4ZN-D2, MY4Z-CR, and MY4ZN-CR

MY Dimensions 10

Miniature Power Relays with Latching Levers: MY(S)

MY2IN (S)
MY2IN-D2 (S)

MY Dimensions 12

MY4 (Z) IN (S)
MY4 (Z) IN-D2 (S)
MY4 (Z) IN-CR (S)

MY Dimensions 13

Relays with PCB Terminals: MY[]-02

Relays with PCB Terminals
MY[]-02

MY Dimensions 15
The figures and dimensions given here are for the MY4-02.
The 2-pole and 3-pole models conform to these dimensions.
* Dimensions in parentheses are for the MY4-02.

Case-surface-mounting Relays: MY[]F

Case-surface mounting
MY[]F

MY Dimensions 17
4 poles, bifurcated contacts
The 1-pole, 2-pole, and 3-pole models conform to these dimensions.

Miniature Power Relays: MY4Z-CBG

MY4Z-CBG

MY Dimensions 19

Plastic Sealed Relays: MYQ

Relays with Plug-in Terminals or Soldered Terminals
MYQ4(Z)(N)

MY Dimensions 21

Relays with PCB Terminals
MYQ4(Z)-02

MY Dimensions 22

Latching Relays: MYK

Relays with Plug-in Terminals or Soldered Terminals
MY2K

MY Dimensions 24

Relays with PCB Terminals
MY2K-02

MY Dimensions 25

Hermetically Sealed Relays: MYH

Relays with Plug-in Terminals or Soldered Terminals
MY4(Z)H

MY Dimensions 27

Relays with PCB Terminals
MY4(Z)H-0

MY Dimensions 28

Mounting Heights with Sockets

Front-mounting Sockets

Screw terminal
(PYF[]A (-E), PYF14T, PYF08M)

MY Dimensions 31
Note: 1. The PYF[]A can be mounted on a track or with screws.
2. The heights given in parentheses are the measurements for 53-mm-high Relays.
3. Use the PYC-P Mounting Bracket for the PYF08M.
Back-mounting Sockets
Solder terminals/Wrapping terminals
(PY[])

MY Dimensions 33
Push-In Plus Terminal Block Sockets
(PYF-[]-PU)

MY Dimensions 34
Relays with PCB Terminals
(PY[]-02)

MY Dimensions 35

Socket Mounting Plate (t = 1.6)

Use a Socket Mounting Plate to mount multiple connection Sockets in a row.

PYP-1

MY Dimensions 37

PYP-18

MY Dimensions 38

PYP-36

MY Dimensions 39