Omron relays. Solid State Relays. G3R-I/O

I/O Solid State Relays
G3R-I/O

SSR with Plug-in Terminals The Same Shape as the G2R-1-S Power Relays

Input Modules for Microloads

Insulation
method
Operation
indicator
Response
speed
Applicable
load
Input rated voltage Model
Photocoupler Yes --- 4 to 32 VDC
0.1 to 100 mA
100 to 240 VAC G3R-IAZR1SN AC100-240
High-speed 5 VDC G3R-IDZR1SN DC5
12 to 24 VDC G3R-IDZR1SN DC12-24
Low-speed 5 VDC G3R-IDZR1SN-1 DC5
12 to 24 VDC G3R-IDZR1SN-1 DC12-24

Output Modules for Standard Loads

Insulation
method
Operation
indicator
Zero cross
function
Applicable load Input rated
voltage
Model
Phototriac Yes Yes 2 A at 100 to 240 VAC 5 to 24 VDC G3R-OA202SZN DC5-24
No G3R-OA202SLN DC5-24
Photocoupler --- 2 A at 5 to 48 VDC G3R-ODX02SN DC5-24
1.5 A at 48 to 200 VDC G3R-OD201SN DC5-24

Accessories (Order Separately)

Connection Sockets

Classification Terminal type Appearance Model
Front-mounting Screw terminals 2808_lu_3_1 P2RF-05
Screw terminals
(finger protection structure)
2808_lu_3_2 P2RF-05-E
Push-In Plus terminal blocks 2808_lu_3_3 P2RF-05-PU
Back-mounting Relays with PCB Terminals 2808_lu_3_4 P2R-05P
2808_lu_3_5 P2R-057P
Solder terminals 2808_lu_3_6 P2R-05A
Refer to Common Socket and DIN Track Products for details on Connection Sockets and DIN Track products (sold separately) of your OMRON website.
Refer to PYF-[][]-PU/P2RF-[][]-PU for details on A Push-In Plus Terminal Block Socket of your OMRON website.

DIN Track Mounting Parts

Classification/division Type Appearance Model
For front-mounting DIN Tracks Shallow type, total length: 1 m 2808_lu_4_1 PFP-100N
Shallow type, total length: 0.5 m PFP-50N
Deep type, total length: 1 m 2808_lu_4_2 PFP-100N2
End Plate 2808_lu_4_3 PFP-M
Spacer 2808_lu_4_4 PFP-S
For back-mounting Mounting Plates for Sockets *
(For 5 Sockets)
--- P2R-P
* Used to mount several P2R-05A Connecting Sockets side by side.

nput Modules for Microloads

Input Side

Model Rated voltage Operating voltage Input current Must-operate
voltage
Must-release
voltage
G3R-IAZR1SN 100 to 240 VAC 60 to 264 VAC 15 mA max. 60 VAC max. 20 VAC min.
G3R-IDZR1SN 5 VDC 4 to 6 VDC 8 mA max. 4 VDC max. 1 VDC min.
G3R-IDZR1SN 12 to 24 VDC 6.6 to 32 VDC 6.6 VDC max. 3.6 VDC min.
G3R-IDZR1SN-1 5 VDC 4 to 6 VDC 4 VDC max. 1 VDC min.
G3R-IDZR1SN-1 12 to 24 VDC 6.6 to 32 VDC 6.6 VDC max. 3.6 VDC min.

Output Side

Model Load voltage Load current
G3R-IAZR1SN 4 to 32 VDC 0.1 to 100 mA
G3R-IDZR1SN
G3R-IDZR1SN
G3R-IDZR1SN-1
G3R-IDZR1SN-1

Output Modules for Standard Loads

Input Side

Model Rated voltage Operating voltage Input current Must-operate
voltage
Must-release
voltage
G3R-OA202SZN 5 to 24 VDC 4 to 32 VDC 15 mA max.
(at 25°C)
4 VDC max. 1 VDC min.
G3R-OA202SLN
G3R-ODX02SN 8mA max.
G3R-OD201SN

Output Side

Model Load voltage Load current *1 Surge withstand current
G3R-OA202SZN 75 to 264 VAC 0.05 to 2 A *2 30 A (60 Hz, 1 cycle)
G3R-OA202SLN
G3R-ODX02SN 4 to 60 VDC 0.01 to 2 A *2 8 A (10 ms)
G3R-OD201SN 40 to 200 VDC 0.01 to 1.5 A *2 8 A (10 ms)
*1. Depends on the ambient temperature. Refer to the reference data Load Current vs. Ambient Temperature Rating on
Data Sheet for details.
*2. The minimum current value is for a temperature of 10°C or higher.

I/O External Display

Lineup includes Input Modules and Output Modules.
The I/O Module classification and AC/DC classification are also indicated in the markings on top of the Relay.

Marking
Specifications
AC IN Input Modules for Microloads, AC input
DC IN Input Modules for Microloads, DC input
AC OUT Output Modules for Standard Loads, AC output
DC OUT Output Modules for Standard Loads, DC output
G3R-I/O Specifications 10

Characteristics

Input Modules for Microloads

Model G3R-IAZR1SN G3R-IDZR1SN G3R-IDZR1SN-1
Operation time 20 ms max. 0.1 ms max. 15 ms max.
Release time
Response frequency 10 Hz 1 kHz 10 Hz
Output ON voltage drop 1.6 V max.
Leakage current 5 μA max.
Insulation resistance 100 MΩ min. between I/O
Dielectric strength 4,000 VAC for 1 min. between I/O
Vibration resistance 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Shock resistance 1,000 m/s2
Storage temperature -30 to 100°C (with no icing)
Ambient operating temperature -30 to 80°C (with no icing)
Ambient operating humidity 45% to 85%
Weight Approx. 18 g

Output Modules for Standard Loads

Model G3R-OA202SZN G3R-OA202SLN G3R-ODX02SN G3R-OD201SN
Operation time 1/2 load power supply
cycle + 1 ms max.
1 ms max.
Release time 1/2 load power supply cycle + 1 ms max. 2 ms max.
Response frequency 20 Hz 100 Hz
Output ON voltage drop 1.6 V max. 2.5 V max.
Leakage current 1.5 mA max. 1 mA max.
Insulation resistance 100 MΩ min. between I/O
Dielectric strength 4,000 VAC for 1 min. between I/O
Vibration resistance 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Shock resistance 1,000 m/s2
Storage temperature -30 to 100°C (with no icing)
Ambient operating temperature -30 to 80°C (with no icing)
Ambient operating humidity 45% to 85%
Weight Approx. 18 g

G3R-I/O

G3R-I/O Dimensions 1

Accessories (Order Separately)

Connection Socket
DIN Track Mounting Parts

Refer to Products Related to Common Sockets and DIN Tracks for precautions on the applicable Sockets of your OMRON website.
Refer to PYF-[][]-PU/P2RF-[][]-PU for precautions on Push-In Plus Terminal Block Sockets of your OMRON website.