• Russian
  • Spain
  • Italy
  • France
  • Deutsch
  • English

Browse All Products

Omron relays. Terminal Relays.

OMRON's Terminal Relay Series contributes to saving space in control panels. They are ideal for output interfaces.

G3S4Terminal SSRG3S4

Compact Terminal SSR with 4 Outputs

G3S4

Terminal SSR
G3S4

Compact Terminal SSR with 4 Outputs

Contact
configuration
Heat sink Built-in SSRs Zero cross
function
Applicable output load Model Rated
voltage
Four SPST-NO relays Yes G3S-201PL-PD No 1 A at 75 to 264 VAC
*1
G3S4-A 5 VDC
12 VDC
24 VDC
No 0.6 A at 75 to 264 VAC
*1
G3S4-A1 5 VDC
12 VDC
24 VDC
Yes G3SD-Z01P-PD 1 A at 3 to 26 VDC
*2
G3S4-D 5 VDC
12 VDC
24 VDC
No 0.6 A at 3 to 26 VDC
*2
G3S4-D1 5 VDC
12 VDC
24 VDC
*1. Given as "250 VAC" on the G3S4.
*2. Given as "24 VDC" on the G3S4.

Accessories (Order Separately)

Connection Sockets (Can be Purchased Individually)

Model Rated voltage
P6BF-4BND 5 VDC
12 VDC
24 VDC

Heat Sinks (Can be Purchased Individually)

Model
Y92B-S10

Replacement Relays

Model Rated voltage
G3S-201PL-PD 5 VDC
12 VDC
24 VDC
G3SD-Z01P-PD 5 VDC
12 VDC
24 VDC

Relay Removal Tool

Applicable Terminal Relays Model
G6B-4CB
G6B-4[][]ND
G3S4
P6B-Y1

Short Bar

(A Short Bar is used to wire crossovers for common terminals for coils or contacts.)

Applicable Terminal Relays
Model
G6B-4CB
G6B-4[][]ND
G3S4
G6B-4-SB

Terminal Cover (Two per Set)

Applicable Terminal Relays Model
G6B-4BND
G6B-47BND
G6B-48BND
G3S4-A1
G3S4-D1
G6B-4-C

Input (per G3S Relay)

Rated
voltage
Operating voltage Must operate level Must release
voltage level
Input impedance Rated current
G3S4-A,
G3S4-A1
G3S4-D,
G3S4-D1
G3S4-A,
G3S4-A1
G3S4-D,
G3S4-D1
DC 5 V 4 to 6 VDC 4 VDC max. 1 VDC min. 440 Ω ±20% 550 Ω ±20% 19.2 mA±20% 15.8 mA±20%
12 V 9.6 to 14.4 VDC 9.6 VDC max. 1 kΩ ±20% 1.2 kΩ ±20% 15.8 mA±20% 12.5 mA±20%
24 V 19.2 to 28.8 VDC 19.2 VDC max. 2.1 kΩ ±20% 2.3 kΩ ±20% 15.7 mA±20% 13.2 mA±20%
Note: The rated current includes the terminal's LED current.

Output (per G3S Relay)

Model Applicable load Load voltage Load current Inrush current resistance
G3S4-A 75 to 264 VAC 0.1 to 1 A 15 A (60 Hz, 1 cycle)
G3S4-A1 0.1 to 0.6 A
G3S4-D 3 to 26 VDC 0.01 to 1 A 3 A (10 ms)
G3S4-D1 0.01 to 0.6 A

Characteristics

Model G3S4-A, G3S4-A1 G3S4-D, G3S4-D1
Must operate time 1 ms max.
Release time 0.5 × load power cycle + 1 ms max. 1 ms max.
Output ON voltage drop 1.6 V max. (RMS) 1.5 V max.
Leakage current 2 mA max. 0.1 mA max. (at 26 VDC)
Insulation resistance 100 MΩ min. (at 500 VDC)
Dielectric strength 2,000 VAC, 50/60 Hz for 1 min
Vibration resistance 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Shock resistance 1,000 m/s2
Storage temperature - 30 to 100 ° C (with no icing)
Ambient operating temperature - 30 to 80 ° C (with no icing)
Ambient operating humidity 45% to 85%
Weight Approx. 95 g (-A model) Approx. 95 g (-D model)

With Heat Sinks

G3S4-A
G3S4-D

G3S4 Dimensions 3

Without Heat Sinks

G3S4-A1
G3S4-D1

G3S4 Dimensions 5

Accessories (Order Separately)

Connection Socket (Can be Purchased Individually)

P6BF-4BND (with operation indicator)
G3S4 Dimensions 8
Mounting Holes (Top View)
G3S4 Dimensions 9

Terminal Arrangement/Internal Connections (Top View)

G3S4 Dimensions 10
Note: Make sure that the polarity of the input terminal is correct.
The polarity given inside parentheses ( ) is for G3S4-D and G3S4-D1 Relays. There is no indication of polarity
when Connection Sockets are used alone.

Heat Sinks (Can be Purchased Individually)

Y92B-S10

G3S4 Dimensions 12

Replacement Relays

G3S-201PL-PD
G3SD-Z01P-PD

G3S4 Dimensions 14
Note: 1. The polarity given inside parentheses ( ) is for DC loads.
2. The load can be connected to ether the positive or negative SSR output terminal.